Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
ezfit:dev:software_meeting_2010-08-02 [2010/08/06 10:31]
smayr
ezfit:dev:software_meeting_2010-08-02 [2011/05/10 12:22] (current)
smayr
Line 1: Line 1:
 == Software Development Meeting 2010-Aug-02 == == Software Development Meeting 2010-Aug-02 ==
  
-Notes relevant to [[ezfit:5.0 Milestones|ezFIT 5.0 Milestones]].+[[ezfit:software_meeting_notes|Software Meeting Notes]] relevant to [[ezfit:5.0 Milestones|ezFIT 5.0 Milestones]].
  
 Attendees: Attendees:
Line 33: Line 33:
     * BTE675DP Fitting (China)     * BTE675DP Fitting (China)
     * HearingCentral     * HearingCentral
-    * Newson +    * Newson (France) 
-    * Newsound +    * Newsound(China) 
-    * Sonitech +    * Sonitech (USA) 
-    * TransEar +    * TransEar (USA) 
-    * Vista HI & A+    * Vista HI & A (USA)
  
   * Challenges:   * Challenges:
Line 60: Line 60:
     * Audina     * Audina
     * Auditiva     * Auditiva
-    * Sonetik +    * Sonetik (Switzerland) 
-    * PHSI+    * PHSI (USA)
  
   * Challenges:   * Challenges:
Line 136: Line 136:
   * Use Audina manufacturer ID code for all products, but differentiate brands by scratch memory code (assigned at Audina internally).  Read this code to determine to whether give access to instrument settings.   * Use Audina manufacturer ID code for all products, but differentiate brands by scratch memory code (assigned at Audina internally).  Read this code to determine to whether give access to instrument settings.
     * Issue: Intuition 2 / Simplex 2P's circuit does not have enough scratch memory to support this feature.      * Issue: Intuition 2 / Simplex 2P's circuit does not have enough scratch memory to support this feature. 
-    * Suggestion: Phase out Intuition 2 / Simplex 2P (DigitalOne2 circuit) in favor of a Spin based circuit (Intuition 2FC) or SpinNR based product (Intuition 2ER).+    * Suggestion: Phase out Intuition 2 / Simplex 2P (DigitalOne2 circuit) in favor of a Spin based product (Intuition 2FC) or SpinNR based product (Intuition 2ER).
  
 ^ Product        ^ Cost (Custom) ^ Cost (BTE) ^ Avg MSRP  ^ ^ Product        ^ Cost (Custom) ^ Cost (BTE) ^ Avg MSRP  ^
Line 142: Line 142:
 | Intuition 2FC  | $55.21        | $85        | $250      | | Intuition 2FC  | $55.21        | $85        | $250      |
 | Intuition 2ER  | $56.21        | N/A        | $275      | | Intuition 2ER  | $56.21        | N/A        | $275      |
 +
 +  * Use a separate QC machine for branding instruments, then process the instrument as normal (with additional checks for correct branding).
 +  * Route all orders (from different brands) to a single database (i.e. using custom ezFIT software should point to same shared databased, to avoid having orders in separate databases).
 +  * Provide single-day registration code in the ezFIT software for dealing with issues out in the field.
  
 Algorithms Algorithms
Line 152: Line 156:
  
 Solutions Guide Solutions Guide
-  * Implement current ezFIT4 Ssolutions Guide.+  * Implement current ezFIT4 Solutions Guide.
  
 == Conclusion == == Conclusion ==
  
   * Next meeting: Aug 16, 2010, 2pm   * Next meeting: Aug 16, 2010, 2pm