Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
ezfit:software_wish_list [2009/08/19 12:15] smayr |
ezfit:software_wish_list [2010/04/28 13:17] (current) ajdavis added import request |
||
---|---|---|---|
Line 16: | Line 16: | ||
* Based on audiogram, provide best suited products that provide that fitting range. | * Based on audiogram, provide best suited products that provide that fitting range. | ||
* Link programming to both sides. | * Link programming to both sides. | ||
+ | * Undo button to undo changes from a history list. | ||
* Move equalizers in group (see Windows Media Player). | * Move equalizers in group (see Windows Media Player). | ||
* Create equalizer object, so all products have same look-n-feel. | * Create equalizer object, so all products have same look-n-feel. | ||
Line 26: | Line 27: | ||
* Custom reports to include dispenser' | * Custom reports to include dispenser' | ||
* RSS announcements fed to software, to inform users. | * RSS announcements fed to software, to inform users. | ||
- | |||
==== Audiograms ==== | ==== Audiograms ==== | ||
- | * The issue is that once the in situ audiogram is selected and saved, that replaces the audiogram in the hearing aid and database. | + | |
+ | * ezFIT 4.x: The issue is that once the in situ audiogram is selected and saved, that replaces the audiogram in the hearing aid and database. | ||
+ | * ezFIT 5.x: Ensure that if a new audiogram is created that this is stored as a session. | ||
+ | === Audiology' | ||
+ | Easier to read font with a little more spacing between characters to make it a little easier on the eyes. | ||
+ | |||
+ | ==== Audiogram Tab ==== | ||
+ | # Ability for practitioner to indicate whether thresholds were measured in dB HL or SPL (it makes a difference) | ||
+ | # Ability for practitioner to record the following on the audiogram: | ||
+ | - Bone conduction thresholds | ||
+ | - Air conduction thresholds | ||
+ | - UCL thresholds (frequency specific) | ||
+ | # Speech Recognition Threshold (SRT) for RE, LE, Binaural | ||
+ | # Most Comfortable Loudness Measures (MCL) for RE, LE, Binaural | ||
+ | # Uncomfortable Loudness Measures (UCL) for RE, LE, Binaural | ||
+ | # Speech Discrimination Scores for RE, LE, & Binaural (recorded | ||
+ | # Automatic calculation of Pure tone Threshold Average (PTA) based on thresholds recorded | ||
+ | - 3 frequency average (500, 1000, 2000 Hz) | ||
+ | - Fletcher average (average of better two frequencies at 500, 1000, 2000 Hz) | ||
+ | # Automatic determination of agreement between SRT and PTA | ||
+ | - +-6 dB of each other = good agreement | ||
+ | - +-7 to +-12 dB of each other = fair agreement | ||
+ | - Difference of +-13 dB or greater = poor agreement | ||
+ | - References: | ||
+ | - Carhart R (1971) Observations on the relations between thresholds | ||
+ | - Fletcher H (1950) A method of calculating hearing loss for speech from an audiogram. | ||
+ | - Brady, W. T. (2002). Speech Audiometry. In J. Katz (Ed.), Handbook of Clinical Audiology (5th Edition ed., pp. 96-110). Philadelphia: | ||
+ | # Additional testing note section | ||
+ | # Inability to change prior audiogram. | ||
+ | # Ability to customize the printout with the company name and information and possibly logo. | ||
+ | |||
+ | ==== Selection Tab ==== | ||
+ | # Ability to select product by using criteria to determine Audina products that will match with hovering providing extra information) | ||
+ | - Technology (Digital, Analog) | ||
+ | - Styles (CIC, Mini canal, canal, half shell, full shell, mini BTE, BTE, Power BTE, Super 60, RIC, Open Fit, Arc) | ||
+ | - Directional Microphones (yes, no, show all) | ||
+ | - Volume Control (yes, no, show all) | ||
+ | - Telecoil (yes, no, show all) | ||
+ | - Multi-Memory (yes, no, show all) | ||
+ | # Once criteria is selected, a list of products with how well they match the criteria is shown (maybe using stars or some other icon to indicate how close a match it is) | ||
+ | # Fitting ranges overlaying the client’s entered audiogram for the various products | ||
+ | # Technical information (think spec sheet) for the products | ||
+ | # Pictures of the hearing device in and out of the ear | ||
+ | # A form field order form so the practitioner can then complete the form and print to mail with the order | ||
+ | - Autofill provider company information from data entered under preferences | ||
+ | ==== Personal Tab ==== | ||
+ | |||
+ | # Button to click to read instruments and go to the fitting screen. | ||
+ | # Button to take a previous session and load the parameters into an instrument of the same family. | ||
+ | |||
+ | ==== Fitting Tab ==== | ||
+ | |||
+ | # Mute Function during fitting: | ||
+ | # Link and unlink RE and LE for making changes | ||
+ | |||
+ | ==== Solutions Tab ==== | ||
+ | # RE, LE, Both Ear option | ||
+ | |||
+ | ==== ezFIT Wizard ==== | ||
+ | |||
+ | EZFit Wizard for first fit | ||
+ | - Select fitting strategy (prescription fitting strategy) | ||
+ | - For RIC and Open Fits select dome/tip size (just for practitioner records) | ||
+ | - Venting | ||
+ | - Earmold | ||
+ | - Earhook |