ezFIT 4 To Do List
ezFIT
For Intricon products, fix Tone reference range for each Input Reference and Output Reference. Each has different ranges.— Siegwart Mayr 2009/07/07 16:03For Intricon products, in Recommended External VC % in Autofit tab (remove this control in favor of the following): * Prompt user for manual adjustment of External VC if current VC is not within required range, i.e. External VC > -5 or External VC > +5 dB (70-80% of Full-on Gain). * After adjusting External VC and selecting < Retry >, perform a automatic refresh of External VC (reading the new value) to verify value is within required range. * Allow user to override this requirement, and proceed with Autofit anyway.Strike-through Text— Joel Jn-François 2009/08/18 16:55For Intricon products with VC Range: * Save Gain level for current External VC. * Autofit and set calculated VC Range. * Restore Gain level for External VC.— Joel Jn-François 2009/08/28 15:32- Allow user to edit Session Notes after the fact.
- Automate Build Process to allow the following:
- Get and build ezFIT executable using Subversion latest updates.
- Create ezFIT CD-ROM images using template stored on the network.
- Allow any authorized user to run build process from their client machine (must be connect to network).
- During fitting, fix graph curve labels which keep displaying after a response curve checkbox is unchecked. (Reported by AJ)
In Situ audiogram being reset back to a standard audiogram once an autofit is performed. (Reported by Barbara)— Siegwart Mayr 2009/08/18 16:54
- A way to take a snapshot of the hearing aid settings across the ezfit paramaters to be dumped into excel as well as the response curve data, for verification purposes and testing. For All products. Basically a data dump so that we can compare it all to the info we get from the Verifit and then have a way to double check settings at the time the tests were run so we can duplicate. Steve is looking for the array of values being generated by the graph to be available. (Reported by Barbara/Steve)
- Streamline Save, Default, and Import operations used in Order Entry. Perhaps create a separate utility to handle those tasks. (Reported by Terri)
- Original settings should be saved to database, for later retrieval.
- Defaults should be loaded to circuit, but not saved to database.
- After QC, original settings should be loaded back to circuit using Import operation.
- Search Patient Record, when performing incremental search and record not found, it defaults to the next record. Provide a prompt or warning to end user, to avoid entering wrong data to unrelated record. (Reported by Terri)
On the Flx when you flip between the ote and bte product using the box in the upper left, the graph title doesn’t change from “open ear coupler” to “2cc coupler” label. However, when you make the change via the advanced tab and change the tubing type it does it fine. (Reported by Barbara)— Joel Jn-Francois 2009/09/04 15:27
- Add 'AutoAdapt Autofit' to list in Tools > Options > Autofit Defaults. If a product does not support it (like non AD products), then default to 'Normal (WDRC). Autofit'. (Requested by Walter Whitney, Vista HIA).
Flx Product
Fix wrong user prompt “Autofit was NOT performed” when autofitting binaurally.— Siegwart Mayr 2009/07/07 16:02Add “MPO apply to All mem” button.Made this into “Sync All Channels” checkbox in Compression tab. — Siegwart Mayr 2009/07/07 14:06Move Digital VC start position to Factory Settings. Only set options to: 100%, 75%, 50%, 25%.— Siegwart Mayr 2009/07/07 11:01Hide Recommended External VC % in Autofit tab. — Siegwart Mayr 2009/07/07 09:54Review In Situ range.— Siegwart Mayr 2009/07/07 14:42Disable Toggle/None button options.— Siegwart Mayr 2009/07/07 17:19Add button to Reset Datalog in Factory Settings tab.— Siegwart Mayr 2009/07/07 13:37- In Datalogging:
- Display graph with number of days worn.
- Fix wrong number of memories shown in Deviation from program gained graph. Test with 1 mem.
- Modify Battery Level graph to display normal battery as High.
- Add button to Copy Settings to Other Side, to be used in binaural fitting.
When autofitting, the hearing aid goes dead until the < Program > button is clicked. (Reported by Barbara Crotty, using 4.21 20090713). Autofit was setting VC Range, and instrument gain was going down. In 4.21 20090730, the changes are heard immediately. — Siegwart Mayr 2009/07/30 16:47Verify MPO settings, not changing, when using Solutions Guide. * Pumping In and Out > Increase MPO (eg. from -10 to > -10).— Siegwart Mayr 2009/08/28 15:27- When programming the hearing aid but deselecting “Save to hearing aid” (i.e. program to database and both ears), only one side is stored. The Hi-Pro only flashes on the one side as well during this process. (Reported by Barbar Crotty, using 4.22 20100504)
Intuition 12
Fix prompt for AutoAdapt autofit when a Normal autofit was selected for a CIC, Mini Canal, and Canal instrument (these styles do not support directional mics). Basically, this prompt should not display for instruments that do not have directional mics.— Siegwart Mayr 2009/07/07 09:34Verify MPO settings, not changing, when using Solutions Guide. * Pumping In and Out > Increase MPO (eg. from -10 to > -10).— Siegwart Mayr 2009/08/28 15:26
Sparo 12
When autofitting, it prompts to set VC to 75%. (Reported by Barbara Crotty)— Siegwart Mayr 2009/08/07 15:16
Sparo 2
- Autofitting a Sparo 2 with 40@250, 40@500, 40@1000, and severe loss at higher frequencies, it generates a spike in the 500 - 1000 kHz range. It can be matched manually using equalizers. (Reported by Nate Strickland)
Intellio
- Add Demo for Live Polar Plot. Switch randomly from Quiet, Restaurant, Noise, and Traffic cardioid patterns. Disable those patterns when connected to a hearing instrument.
- Add Demo for Auto Environment Detection (iSceneDetect). Show environments graphically, and randomly change between them. Reduce the transition time to 1 or 2 seconds, instead of the 20 sec minimum when used with a connected hearing instrument.
- Occlusion Manager, calling the Solutions Guide behind the scenes.
- Remove Feedback Path feature (until further notice).
- Add Autofits:
- AutoAdapt: switches the Auto ADM input automatically.
- AutoEnvironment: switches the Auto Environment Detection (iSceneDetect) input automatically.
- Rename FrontWave to Directional.
- In Situ Range. Extend the limited range of in situ tones to something more useful. Steve needs to make this decision and talk directly to Sound Design to decide what DLL is going to be used. These changes are applied manually by Sound Design.
- Simplify terms for AutoEnvironment Detection. Provide simple screen, and advanced screen with full access to parameters.
- Music sensitivity
- Speed of Environment detection
Action Plan
- NAL autofit in process.
- Action: AJ
- VC analog and digital available will need to be specified at time of order.
- Solution guide in process.
- Action: Barbara
- Corfigs for styles.
- Action: Steve
- Figures (like corfigs) for the open dome vs. power dome vs. closed dome for slim tubes. Ideally take into account vent size as well.
- iSceneDetect will be on a tab as on/off option.
- Time constants?
- Programming speed: still of concern.
- BTE/open housing for Intellio.
- Action: Dale
- Wire up Flx case for Intellio as soon as sound design boards come in (est. Dec 14, 2009).
- Physical sample Intellio flx.
- Action: Dale
- Software BTE targets.
- Action: AJ
- Software ready for testing and limited trials within 2 weeks (Dec 14, 2009).
- January 2010 anticipated release.
- Meetings on Monday afternoons following Joel’s lunch (2:30pm) in conference room for updates.
TransEar
- Add Factory Settings tab, exposing Firmware Version, Load Defaults (from Config files).
- Add support to load default settings from file (PGM files).
Foundation / BTE 478P
Add Configuration Utility to recalibrate Foundation and BTE 478P products to work with new single-use DLLs.— Joel Jn-Francois 2009/09/17 16:44
ezHIT
Add support for Frye Fonix 7000. (for Glenn)— Siegwart Mayr 2009/07/07 09:36Add button to change to Telecoil memory during ANSI96 test. (for Dale)— Siegwart Mayr 2009/07/07 09:36Support for Private Label (i.e. Auditiva) reports. (Guillermo)— Siegwart Mayr 2009/07/09 15:24Bug: Check Measured Ref Test Gain (RTG). It is not adjusting. It should be within + or - 1.5 dB from Target RTG.— Siegwart Mayr 2009/08/07 15:17Bug: Settings > General > Private label = No Label, should default to no logo in final report.— Siegwart Mayr 2009/08/07 15:17Add Directional Mic Calibration support. (for Dale)— Siegwart Mayr 2009/07/20 11:50Detect feedback before starting ANSI96 test. * Spectrum Mode (press 0/60 button), to set Source Off. * Read RMS Out. RMS = Root Mean Square * If input/output reference number (RMS Out) > 65 dB, we have feedback, else test passed. (Glenn)— Siegwart Mayr 2009/08/11 13:13Bug: Allow ANSI96 test to enable/disable battery drain when using Fonix 7000.— Siegwart Mayr 2009/08/11 13:13Report file name (report title when sending to printer) should include product and serial number, to simplify saving PDF files.— Siegwart Mayr 2009/09/17 16:45